| Construction Materials |
| Jacket Material |
Unjacketed |
| Conductor Material |
Corrugated copper |
| |
| Dimensions |
| Cable Volume |
5621.0 L/km | 60.5 ft³/kft |
| Cable Weight |
2.76 kg/m | 1.85 lb/ft |
| Diameter Over Jacket (E Plane) |
127.50 mm | 5.02 in |
| Diameter Over Jacket (H Plane) |
71.90 mm | 2.83 in |
| |
| Electrical Specifications |
| Operating Frequency Band |
2.3 – 2.4 GHz |
| eTE11 Mode Cutoff |
1.570 GHz |
| Group Delay |
128 ns/100 ft @ 2.600 GHz | 418 ns/100 m @ 2.600 GHz |
| |
| Environmental Specifications |
| Installation Temperature |
-40 °C to +60 °C (-40 °F to +140 °F) |
| Operating Temperature |
-55 °C to +85 °C (-67 °F to +185 °F) |
| Storage Temperature |
-70 °C to +85 °C (-94 °F to +185 °F) |
| |
| Mechanical Specifications |
| Maximum Twist |
0.75 °/m | 0.03 °/ft |
| Minimum Bend Radius, Multiple Bends (E Plane) |
660.00 mm | 26.00 in |
| Minimum Bend Radius, Multiple Bends (H Plane) |
1800.00 mm | 71.00 in |
| Minimum Bend Radius, Single Bend (E Plane) |
460.00 mm | 18.00 in |
| Minimum Bend Radius, Single Bend (H Plane) |
1270.00 mm | 50.00 in |
| |
| Standard Conditions |
| Attenuation, Ambient Temperature |
24 °C | 75 °F |
| Average Power, Ambient Temperature |
40 °C | 104 °F |
| Average Power, Temperature Rise |
42 °C | 76 °F |