| Construction Materials |
| Jacket Material |
PE |
| Conductor Material |
Corrugated copper |
| Jacket Color |
Black |
| |
| Dimensions |
| Cable Volume |
585.0 L/km | 6.3 ft³/kft |
| Cable Weight |
0.67 kg/m | 0.45 lb/ft |
| Diameter Over Jacket (E Plane) |
43.60 mm | 1.72 in |
| Diameter Over Jacket (H Plane) |
25.40 mm | 1.00 in |
| |
| Electrical Specifications |
| Operating Frequency Band |
7.725 – 8.5 GHz |
| eTE11 Mode Cutoff |
4.720 GHz |
| Group Delay |
128 ns/100 ft @ 7.800 GHz | 419 ns/100 m @ 7.800 GHz |
| |
| Environmental Specifications |
| Installation Temperature |
-40 °C to +60 °C (-40 °F to +140 °F) |
| Operating Temperature |
-55 °C to +85 °C (-67 °F to +185 °F) |
| Storage Temperature |
-70 °C to +85 °C (-94 °F to +185 °F) |
| |
| Mechanical Specifications |
| Maximum Twist |
3.00 °/m | 1.00 °/ft |
| Minimum Bend Radius, Multiple Bends (E Plane) |
230.00 mm | 9.00 in |
| Minimum Bend Radius, Multiple Bends (H Plane) |
635.00 mm | 25.00 in |
| Minimum Bend Radius, Single Bend (E Plane) |
180.00 mm | 7.00 in |
| Minimum Bend Radius, Single Bend (H Plane) |
510.00 mm | 20.00 in |
| |
| Standard Conditions |
| Attenuation, Ambient Temperature |
24 °C | 75 °F |
| Average Power, Ambient Temperature |
40 °C | 104 °F |
| Average Power, Temperature Rise |
42 °C | 76 °F |