| Construction Materials |
| Jacket Material |
PE |
| Conductor Material |
Corrugated copper |
| Jacket Color |
Black |
| |
| Dimensions |
| Cable Volume |
390.0 L/km | 4.2 ft³/kft |
| Cable Weight |
0.50 kg/m | 0.33 lb/ft |
| Diameter Over Jacket (E Plane) |
33.50 mm | 1.32 in |
| Diameter Over Jacket (H Plane) |
22.90 mm | 0.90 in |
| |
| Electrical Specifications |
| Operating Frequency Band |
8.5 – 9.8 GHz |
| eTE11 Mode Cutoff |
6.460 GHz |
| Group Delay |
143 ns/100 ft @ 9.200 GHz | 468 ns/100 m @ 9.200 GHz |
| |
| Environmental Specifications |
| Installation Temperature |
-40 °C to +60 °C (-40 °F to +140 °F) |
| Operating Temperature |
-55 °C to +85 °C (-67 °F to +185 °F) |
| Storage Temperature |
-70 °C to +85 °C (-94 °F to +185 °F) |
| |
| Mechanical Specifications |
| Maximum Twist |
3.00 °/m | 1.00 °/ft |
| Minimum Bend Radius, Multiple Bends (E Plane) |
200.00 mm | 8.00 in |
| Minimum Bend Radius, Multiple Bends (H Plane) |
480.00 mm | 19.00 in |
| Minimum Bend Radius, Single Bend (E Plane) |
200.00 mm | 8.00 in |
| Minimum Bend Radius, Single Bend (H Plane) |
480.00 mm | 19.00 in |
| |
| Standard Conditions |
| Attenuation, Ambient Temperature |
24 °C | 75 °F |
| Average Power, Ambient Temperature |
40 °C | 104 °F |
| Average Power, Temperature Rise |
42 °C | 76 °F |