| Construction Materials |
| Jacket Material |
PE |
| Conductor Material |
Corrugated copper |
| Jacket Color |
Black |
| |
| Dimensions |
| Cable Volume |
56.0 L/km | 0.6 ft³/kft |
| Cable Weight |
0.16 kg/m | 0.11 lb/ft |
| Diameter Over Jacket (E Plane) |
15.20 mm | 0.60 in |
| Diameter Over Jacket (H Plane) |
9.65 mm | 0.38 in |
| |
| Electrical Specifications |
| Operating Frequency Band |
24.0 – 26.5 GHz |
| eTE11 Mode Cutoff |
15.190 GHz |
| Group Delay |
127 ns/100 ft @ 25.300 GHz | 417 ns/100 m @ 25.300 GHz |
| |
| Environmental Specifications |
| Installation Temperature |
-40 °C to +60 °C (-40 °F to +140 °F) |
| Operating Temperature |
-55 °C to +85 °C (-67 °F to +185 °F) |
| Storage Temperature |
-70 °C to +85 °C (-94 °F to +185 °F) |
| |
| Mechanical Specifications |
| Maximum Twist |
6.00 °/m | 2.00 °/ft |
| Minimum Bend Radius, Multiple Bends (E Plane) |
4.00 mm | 120.00 in |
| Minimum Bend Radius, Multiple Bends (H Plane) |
9.00 mm | 230.00 in |
| Minimum Bend Radius, Single Bend (E Plane) |
4.00 mm | 120.00 in |
| Minimum Bend Radius, Single Bend (H Plane) |
9.00 mm | 230.00 in |
| |
| Standard Conditions |
| Attenuation, Ambient Temperature |
24 °C | 75 °F |
| Average Power, Ambient Temperature |
40 °C | 104 °F |
| Average Power, Temperature Rise |
42 °C | 76 °F |