Home > Systems > Antenna Cabling > Andrew Cable > Andrew Cable: Cinta > Andrew CNT-240

Andrew Cable: Cinta
Andrew CNT-240

Andrew CNT-240
Code: CNT-240

Please contact us for pricing information. 877-288-6139


The Andrew CNT-240 is a CINTA series cable. The impedance is 50Ω, the maximum frequency is 31 GHz, and the peak power is 5.6 kW.

Impedance50Ω
Max Frequency39 GHz
Velocity83.00%
Voltage Withstand1000 VDC
Peak Power2.5 kW
DC ResistanceInner: 5.36Ω/1000 ft; 17.59Ω/1000 m / Outer: 4.9Ω/1000 ft; 16.08Ω/1000 m
Jacket Spark3000 VRMS
Capacitance24.5 ρF/ft / 80.4 ρF/m
Inductance0.061 μH/ft / 0.20 μH/m
Shielding Effectiveness> 90 dB
Phase Stability< 10 ppm/°C
Jacket ColorBlack
Outer Conductor MaterialAluminum Tape
Inner Conductor MaterialSolid BC
Dielectric MaterialFoam Polyethylene
Overall Braid MaterialTinned Copper
Jacket MaterialPolyethylene
Cable MaterialPolyethylene, Standard outdoor cable
Diameter over Jacket, Standard Jacket0.195 in / 4.95 mm
Overall Braid Diameter0.144 in / 3.66 mm
Diameter Outer Conductor0.121 in / 3.07 mm
Dielectric Diameter0.116 in / 2.95 mm
Diameter Inner Conductor0.044 in / 1.12 mm
Min Bending Radius0.5 in / 12.7 mm
Bending Moment0.2 lbs/ft / 0.27 N/m
Cable Weight0.022 lbs/ft / 0.03 kg/m
Tensile Strength40 lbs / 18.2 kg
Flat Plate Crush Strength15 lbs/in / 0.27 kg/mm
Operating Temperature-40°C to +85°C / -40°F to +185°F
Installation Temperature-40°C to +85°C / -40°F to +185°F
Storage Temperature-70°C to +85°C / -94°F to +185°F
30 MHzAttenuation: 1.8 dB/100 ft; 5.8 dB/100 m at 20°C / Avg Pwr: 1.02 kW at Ambient 40°C, Inner conductor 100°C
50 MHzAttenuation: 2.3 dB/100 ft; 7.4 dB/100 m at 20°C / Avg Pwr: 0.79 kW at Ambient 40°C, Inner conductor 100°C
150 MHzAttenuation: 4.0 dB/100 ft; 13.0 dB/100 m at 20°C / Avg Pwr: 0.45 kW at Ambient 40°C, Inner conductor 100°C
220 MHzAttenuation: 4.8 dB/100 ft; 15.7 dB/100 m at 20°C / Avg Pwr: 0.37 kW at Ambient 40°C, Inner conductor 100°C
450 MHzAttenuation: 6.9 dB/100 ft; 22.6 dB/100 m at 20°C / Avg Pwr: 0.26 kW at Ambient 40°C, Inner conductor 100°C
900 MHzAttenuation: 9.8 dB/100 ft; 32.3 dB/100 m at 20°C / Avg Pwr: 0.18 kW at Ambient 40°C, Inner conductor 100°C
1500 MHzAttenuation: 12.8 dB/100 ft; 42.0 dB/100 m at 20°C / Avg Pwr: 0.14 kW at Ambient 40°C, Inner conductor 100°C
1800 MHzAttenuation: 14.1 dB/100 ft; 46.1 dB/100 m at 20°C / Avg Pwr: 0.13 kW at Ambient 40°C, Inner conductor 100°C
2000 MHzAttenuation: 14.9 dB/100 ft; 48.8 dB/100 m at 20°C / Avg Pwr: 0.12 kW at Ambient 40°C, Inner conductor 100°C
2500 MHzAttenuation: 16.7 dB/100 ft; 54.8 dB/100 m at 20°C / Avg Pwr: 0.10 kW at Ambient 40°C, Inner conductor 100°C

Previous Product Next Product